Preclinical Systolic and Diastolic Dysfunction Assessed by Tissue Doppler Imaging is Associated With Elevated Plasma Pro-B-type Natriuretic Peptide Concentrations

Abstract Background Heart failure is a major public health problem. To improve its grave prognosis, early identification of cardiac dysfunction is mandatory. Conventional echocardiography is not suitable for this. Tissue Doppler imaging (TDI), however, could be so. Methods and Results Within a large...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiac failure 2009-08, Vol.15 (6), p.489-495
Hauptverfasser: Mogelvang, Rasmus, MD, Goetze, Jens P., MD, DMSC, Pedersen, Sune A., MD, Olsen, Niels T., MD, Marott, Jacob L., MSc, Schnohr, Peter, MD, Sogaard, Peter, MD, DMSC, Jensen, Jan S., MD, PhD, DMSC
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Heart failure is a major public health problem. To improve its grave prognosis, early identification of cardiac dysfunction is mandatory. Conventional echocardiography is not suitable for this. Tissue Doppler imaging (TDI), however, could be so. Methods and Results Within a large community-based population-study (n = 1012), cardiac function was evaluated by conventional echocardiography (left ventricular hypertrophy, dilatation, systolic, and severe diastolic dysfunction), TDI, and plasma proBNP. Averages of peak systolic (s′), early diastolic (e′), and late diastolic (a′) velocities from 6 mitral annular sites were used. TDI was furthermore quantified by a combined index (eas-index) of diastolic and systolic performance: e′/(a′ × s′). Compared with controls, persons with elevated plasma proBNP concentrations (n = 100) displayed lower systolic and diastolic performance by TDI, in terms of lower s′ ( P = 0.017) and a′ ( P < .001), and higher e′/a′ ( P = .002) and eas-index ( P < .001). This pattern remained significant after multivariable adjustment for age, sex, body mass index, heart rate, estimated glomerular filtration rate, hypertension, diabetes, ischemic heart disease, and conventional echocardiography. Furthermore, TDI provided incremental information over conventional echocardiography in predicting elevated plasma proBNP concentrations. Conclusions Preclinical systolic and diastolic dysfunction by TDI is associated with elevated plasma proBNP levels, even when conventional echocardiography is normal.
ISSN:1071-9164
1532-8414
DOI:10.1016/j.cardfail.2009.01.005