Pressure-Guided Cryoballoon Isolation of the Pulmonary Veins for the Treatment of Paroxysmal Atrial Fibrillation

Pressure‐Guided Cryoballoon Pulmonary Vein Isolation. Background: Pulmonary vein (PV) isolation using a balloon‐mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Complete PV occlusion during balloon ablation has been shown to predict successf...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiovascular electrophysiology 2010-02, Vol.21 (2), p.120-125
Hauptverfasser: SIKLÓDY, CLAUDIA HERRERA, MINNERS, JAN, ALLGEIER, MARTIN, ALLGEIER, HANS-JÜRGEN, JANDER, NIKOLAUS, KEYL, CORNELIUS, WEBER, REINHOLD, SCHIEBELING-RÖMER, JOCHEN, KALUSCHE, DIETRICH, ARENTZ, THOMAS
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Pressure‐Guided Cryoballoon Pulmonary Vein Isolation. Background: Pulmonary vein (PV) isolation using a balloon‐mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Complete PV occlusion during balloon ablation has been shown to predict successful electrical isolation. The aim of this study was to correlate mechanical PV occlusion with changes in a pressure curve recorded at the distal tip of the cryoballoon catheter. Methods and Results: We analyzed 51 PVs in 12 patients (61 ± 6 years old) with paroxysmal AF. At first, PV occlusion via the cryoballoon was documented by changes in the pressure curve. Once the PV is occluded, the pressure curve registered in the vein converts from a left atrial pressure curve to a pulmonary artery pressure curve: the PV wedge curve. Occlusion was then confirmed by transesophageal echocardiography (TEE). Following 2 cryoablation applications, electrical PV isolation was assessed with a circumferential mapping catheter. Under the exclusive guidance of changes in the pressure curve at the tip of the cryoballoon, mechanical occlusion confirmed by TEE was achieved in 47 of 51 PVs (92%). Three PVs required further TEE guidance to achieve occlusion. All 50 occluded veins were electrically isolated after cryoablation. One right inferior vein, which could not be occluded with the balloon, displayed conduction post cryoablation and was isolated by focal ablation. Conclusions: Occlusion and electrical isolation of PVs during cryoballoon ablation can be predicted by the appearance of a PV wedge curve at the tip of the catheter. This new straightforward parameter may facilitate the procedure. (J Cardiovasc Electrophysiol, Vol. 21, pp. 120‐125, February 2010)
ISSN:1045-3873
1540-8167
DOI:10.1111/j.1540-8167.2009.01600.x