Automatic real-time detection of myocardial ischemia by epicardial accelerometer

Objective Myocardial ischemia may be detected with epicardial accelerometers. We developed and tested automated algorithms for real-time detection of myocardial ischemia by accelerometer measurements in both experimental and clinical settings. Methods In 10 pigs, an accelerometer was fixed to the ep...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 2010-04, Vol.139 (4), p.1026-1032
Hauptverfasser: Halvorsen, Per Steinar, MD, Remme, Espen W., MSc, PhD, Espinoza, Andreas, MD, Skulstad, Helge, MD, PhD, Lundblad, Runar, MD, PhD, Bergsland, Jacob, MD, Hoff, Lars, MSc, PhD, Imenes, Kristin, MSc, PhD, Edvardsen, Thor, MD, PhD, Elle, Ole Jakob, MD, PhD, Fosse, Erik, MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective Myocardial ischemia may be detected with epicardial accelerometers. We developed and tested automated algorithms for real-time detection of myocardial ischemia by accelerometer measurements in both experimental and clinical settings. Methods In 10 pigs, an accelerometer was fixed to the epicardium in the area perfused by left anterior descending coronary artery. Acceleration and electrocardiogram were simultaneously recorded, and the QRS complex was automatically detected for exact timing of systole. Peak circumferential velocity and displacement were automatically calculated from epicardial acceleration signal within 150 milliseconds after peak R on electrocardiography. Global myocardial function was reduced by esmolol infusion, and regional function was altered by temporary left anterior descending occlusion. Automated ischemia detection analyses were tested in 7 patients during off-pump coronary artery bypass grafting. Left anterior descending coronary artery was occluded for 3 minutes before grafting. In both models, echocardiographic myocardial circumferential strain was used to confirm ischemia. Results Systolic displacement changed most during left anterior descending occlusion. Negative displacement during ischemia was found in pigs (11.5 ± 2.3 to −1.2 ± 2.8 mm, P < .01); regional hypokinesia was found in clinical study (12.8 ± 8.1 to 3.5 ± 4.4 mm, P < .01). Ischemia was confirmed by echocardiography in both settings. Esmolol infusion induced smaller changes in automated accelerometer measurements than did left anterior descending occlusion ( P < .01). Conclusions Automatic real-time detection of myocardial ischemia with epicardial accelerometer was feasible. Automated ischemia detection analysis may be used for continuous monitoring of myocardial ischemia during cardiac surgery.
ISSN:0022-5223
1097-685X
DOI:10.1016/j.jtcvs.2009.05.031