Fracture healing monitored with strain gauges: External fixation of 7 humeral neck fractures
We measured healing in 7 cases of surgical neck fracture of the humerus by applying a strain gauge measuring bar between the external fixation pins. Repeated measurements provided a healing curve for the individual cases. The gradual decrease in deflection of the fracture zone reached a plateau of a...
Gespeichert in:
Veröffentlicht in: | Acta orthopaedica Scandinavica 1992-12, Vol.63 (6), p.612-614 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We measured healing in 7 cases of surgical neck fracture of the humerus by applying a strain gauge measuring bar between the external fixation pins. Repeated measurements provided a healing curve for the individual cases. The gradual decrease in deflection of the fracture zone reached a plateau of about 50 percent after 2 to 4 weeks in 6 cases. Removal of the frame at this time proved safe, as solid healing occurred. In one fracture no such decrease was seen and nonunion developed. |
---|---|
ISSN: | 0001-6470 |
DOI: | 10.1080/17453679209169719 |