Constrained liners for recurrent dislocations in total hip arthroplasty

This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA). Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hip international 2007-04, Vol.17 (2), p.78-81
Hauptverfasser: Knudsen, R, Ovesen, O, Kjaersgaard-Andersen, P, Overgaard, S
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA). Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27 months (range 7-77 months). During the observation period five patients had to be revised: one for deep infection and four on account of re-dislocations. Our results indicate that patients with recurrent THA dislocations can be treated with a CL and has a satisfactory low complication rate and a relatively low risk of re-dislocation.
ISSN:1120-7000
1724-6067
DOI:10.1177/112070000701700204