Constrained liners for recurrent dislocations in total hip arthroplasty
This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA). Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27...
Gespeichert in:
Veröffentlicht in: | Hip international 2007-04, Vol.17 (2), p.78-81 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA). Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27 months (range 7-77 months). During the observation period five patients had to be revised: one for deep infection and four on account of re-dislocations. Our results indicate that patients with recurrent THA dislocations can be treated with a CL and has a satisfactory low complication rate and a relatively low risk of re-dislocation. |
---|---|
ISSN: | 1120-7000 1724-6067 |
DOI: | 10.1177/112070000701700204 |