Treatment of Age-Related Hearing Loss in Dogs with the Vibrant Soundbridge Middle Ear Implant: Short-Term Results in 3 Dogs

Background: Age‐related hearing loss (ARHL), or presbycusis, is the most common form of acquired hearing loss in dogs. Middle ear implants have been used successfully in people with ARHL who cannot benefit from conventional hearing aids. Hypothesis: Audibility improves in dogs with ARHL after implan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of veterinary internal medicine 2010-05, Vol.24 (3), p.557-564
Hauptverfasser: Ter Haar, G., Mulder, J.J., Venker-van Haagen, A.J., Van Sluijs, F.J., Snik, A.F., Smoorenburg, G.F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Age‐related hearing loss (ARHL), or presbycusis, is the most common form of acquired hearing loss in dogs. Middle ear implants have been used successfully in people with ARHL who cannot benefit from conventional hearing aids. Hypothesis: Audibility improves in dogs with ARHL after implantation of the Vibrant Soundbridge (VSB) middle ear implant. Animals: Three Beagle dogs with ARHL, mean age 11.1 years. Methods: The dogs were assessed pre‐ and postoperatively by brainstem‐evoked response audiometry (BERA), otoscopy, and computed tomography scans of the ears. A VSB middle ear implant was implanted unilaterally. Three months later the functionality of the implants was assessed by auditory steady‐state responses (ASSRs), after which the dogs were euthanized for histopathological examination. Results: The VSB was implanted successfully in all dogs. Recovery from surgery was uneventful, except for transient facial nerve paralysis in 2 dogs. ASSRs showed that hearing improved after activation of the implants with a mean of 20.7, 13, and 16.3 dB at 1, 2, and 4 kHz, respectively. The implantation procedure did not affect residual hearing (with inactive implants) as measured by BERA. Conclusions and Clinical Importance: Implantation of the VSB resulted in lower ASSR thresholds, but only at the higher gain settings of the audioprocessor. As in humans, a more powerful audioprocessor is required to treat sensorineural hearing loss exceeding 20 dB in dogs. A substantial improvement in patient‐owner communication will have to be demonstrated in future studies before the procedure can be recommended in clinical practice.
ISSN:0891-6640
1939-1676
DOI:10.1111/j.1939-1676.2010.0486.x