Transrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: Mid-term results
Purpose: We evaluated mid-term results of a single-center consecutive series of endovascular stent-grafts implanted for aortic aneurysm repair with transrenal fixation, to determine clinical outcome, aneurysm anatomy, renal artery patency, and renal complications. Methods: Modular stent-grafts were...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery 2003-05, Vol.37 (5), p.938-942 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: We evaluated mid-term results of a single-center consecutive series of endovascular stent-grafts implanted for aortic aneurysm repair with transrenal fixation, to determine clinical outcome, aneurysm anatomy, renal artery patency, and renal complications. Methods: Modular stent-grafts were placed with transrenal fixation in 37 patients between November 1998 and July 2000. Follow-up evaluation included clinical examination, laboratory evaluation of serum creatine concentration, computed tomographic angiography, and renal duplex scanning. Results: Thirty-seven patients underwent transrenal fixation of aortic stent-grafts as part of a Phase II US Food and Drug Administration study. Two patients subsequently underwent follow-up at institutions closer to their homes, and thus provided clinical information but no long-term renal or aneurysm morphologic data. There were no perioperative deaths. Five patients died during follow-up, at a mean of 9 months, because of myocardial infarction in 4 patients and respiratory failure in 1 patient. Thirty patients, ages 75 ± 8 years, have been followed up for 28.5 ± 7.2 months. Aneurysm diameter at follow-up was 5.0 ± 0.8 cm, compared with 5.7 ± 0.8 cm preoperatively. In 5 patients, endoleak developed during follow-up: 1 type I leak was treated with an aortic cuff, with temporary stabilization of the aneurysm and correction of the endoleak; 2 type II endoleaks were treated with translumbar coil embolization, and 1 resolved spontaneously; and 1 type III endoleak was treated with a combination of coil embolization and stent-graft extension to cover a graft defect. Preoperatively, serum creatinine concentration was normal in 23 patients, but increaesd persistently in 2 patients and was abnormal in 7 patients. Postoperatively, creatine concentration increased in 4 patients to greater than 20% of baseline level. Seventeen patients had no evidence of renal artery stenosis, compared with 13 patients with renal artery stenosis. Of 41 normal renal arteries, 90% remained unchanged, 1 became occluded, 3 demonstrated 60% stenosis. Nephrectomy was necessary in 1 patient because of cancer. Of 19 abnormal renal arteries, progression of disease was noted in 3 arteries. Conclusions: Transrenal fixation of aortic stent-grafts can be performed with acceptable mid-term outcome with respect to mortality, need for follow-up intervention, and aneurysm exclusion with protection from rupture. Postprocedural stenosis can develop in both norm |
---|---|
ISSN: | 0741-5214 1097-6809 |
DOI: | 10.1067/mva.2003.228 |