Neonatal phrenic nerve paralysis resulting from intercostal drainage of pneumothorax

Four cases of phrenic nerve paralysis complicating chest tube placement in the newborn for pneumothorax are presented. This complication is related to abnormal location of the medial end of the chest tube. It is suggested that on the frontal chest radiograph, the medial end of the chest tube should...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatric radiology 1992-09, Vol.22 (5), p.379-381
Hauptverfasser: ODITA, J. C, KHAN, A. S. S. I, DINCSOY, M, KAYYALI, M, MASOUD, A, AMMARI, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Four cases of phrenic nerve paralysis complicating chest tube placement in the newborn for pneumothorax are presented. This complication is related to abnormal location of the medial end of the chest tube. It is suggested that on the frontal chest radiograph, the medial end of the chest tube should be no less than 1 cm from the spine.
ISSN:0301-0449
1432-1998
DOI:10.1007/bf02016263