Diagnostic value of ultrasonography in partial ruptures of the Achilles tendon

We evaluated 37 patients with surgically treated Achilles tendon disorders, comparing findings of pre operative ultrasonography with findings at surgery, to investigate the reliability of ultrasonography in diagnos ing partial ruptures of the Achilles tendon. Discontinuity of tendon fibers, focal so...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of sports medicine 1992-07, Vol.20 (4), p.378-381
Hauptverfasser: Kälebo, Peter, Allenmark, Christer, Peterson, Lars, Swärd, Leif
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We evaluated 37 patients with surgically treated Achilles tendon disorders, comparing findings of pre operative ultrasonography with findings at surgery, to investigate the reliability of ultrasonography in diagnos ing partial ruptures of the Achilles tendon. Discontinuity of tendon fibers, focal sonolucencies, and localized tendon swelling were positive findings suggestive of partial ruptures. We found the use of ultrasonography to be safe and reliable, with a sensitivity of 0.94, a specificity of 1.00, and an overall accuracy of 0.95.
ISSN:0363-5465
1552-3365