Intraoperative monitoring of tibialis anterior muscle motor evoked responses to transcranial electrical stimulation during partial neuromuscular blockade
We studied the feasibility of recording motor evoked responses to transcranial electrical stimulation (tce-MERs) during partial neuromuscular blockade (NMB). In 11 patients, compound muscle action potentials were recorded from the tibialis anterior muscle in response to transcranial electrical stimu...
Gespeichert in:
Veröffentlicht in: | Anesthesia and analgesia 1992-10, Vol.75 (4), p.584-589 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We studied the feasibility of recording motor evoked responses to transcranial electrical stimulation (tce-MERs) during partial neuromuscular blockade (NMB). In 11 patients, compound muscle action potentials were recorded from the tibialis anterior muscle in response to transcranial electrical stimulation during various levels of vecuronium-induced NMB. The level of NMB was assessed by accelerometry of the adductor pollicis muscle after train-of-four stimulation of the ulnar nerve. The compound muscle action potential was also recorded from the tibialis anterior muscle after direct stimulation of the peroneal nerve (M-response) as an alternative means of assessing the degree of NMB. In all patients, tce-MERs could be recorded reliably during anesthesia with N2O and a continuous infusion of sufentanil (0.5 micrograms.kg-1.h-1). An intact train-of-four was present in all patients, and the amplitude of the first twitch was recorded and designated as the control value. Before administration of vecuronium, the M-response amplitude was 9.6 +/- 3.6 (mean +/- SD) mV, and the tce-MER amplitude was 1.21 +/- 0.66 mV. Although administration of vecuronium (0.05 mg/kg) resulted in loss of the mechanical adductor pollicis response in 8 of the 11 patients, the M-response and the tce-MER remained recordable. Subsequently, during an infusion of vecuronium, adjusted to maintain one or two mechanical responses to train-of-four stimulation, the average M-response to peroneal nerve stimulation was 5.2 +/- 2.5 mV (53% of the control value), and tce-MER amplitude was 0.59 +/- 0.36 mV (59% of the control value). |
---|---|
ISSN: | 0003-2999 1526-7598 |
DOI: | 10.1213/00000539-199210000-00021 |