Comparison of Clinical and Urodynamic Outcome in Orthotopic Ileocaecal and Ileal Neobladder
Objective: Aim of this study was to evaluate the clinical and urodynamic results in patients who had undergone orthotopic bladder substitution with ileocaecal (Mainz pouch procedure) or ileal (Abol-Enein and Ghoneim procedure) segments and who had a minimum follow-up of 12 months. Methods: Mainz pou...
Gespeichert in:
Veröffentlicht in: | European urology 2003-03, Vol.43 (3), p.258-262 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective:
Aim of this study was to evaluate the clinical and urodynamic results in patients who had undergone orthotopic bladder substitution with ileocaecal (Mainz pouch procedure) or ileal (Abol-Enein and Ghoneim procedure) segments and who had a minimum follow-up of 12 months.
Methods:
Mainz pouch procedure (MP) was performed in 19 patients (mean age 62.4 years, median follow-up 36 months) and Abol-Enein and Ghoneim procedure (AG) in 36 patients (mean age 64.3 years, median follow-up 31 months). Complications and urodynamic findings were compared in both groups.
Results:
Complications related to the pouch were (MP and AG groups, respectively) ureterointestinal anastomotic stenosis (10.5% versus 5.7%), poucho-urethral anastomosis stenosis (5.3% versus 5.5%), poucho-ureteral reflux (7.9% versus 4.2%), and pyelonephritis (15.8% versus 13.8%). At 12 months postoperatively, daytime incontinence rates were 5.3% versus 5.5% and nighttime incontinence (twice weekly or more) rates were 21% versus 8.4% in MP and AG groups. In urodynamic evaluation, which was performed in 39 patients at 12 months postoperatively, both groups showed adequate bladder capacity, the mean values of which were 426±34
ml in MP group and 442±27
ml in AG group (
p>0.05). The mean value of maximal flow rate was 19.6±3.7
ml/s in MP group and 16±6.1
ml/s in AG group (
p>0.05). The mean residual urinary volume was 37±8.2
ml in MP group and 45±7.1
ml in AG group (
p>0.05).
Conclusion:
The comparison between two types of bladder substitution, namely ileocaecourethrostomy (Mainz pouch procedure) and ileal reservoir (Abol-Enein and Ghoneim procedure) has demonstrated that urodynamic findings showed no significant difference between two groups. |
---|---|
ISSN: | 0302-2838 1873-7560 |
DOI: | 10.1016/S0302-2838(03)00042-3 |