Occlusive wrap dressing reduces infection rate in saphenous vein harvest site
Infection in the saphenous vein harvest site is a common problem. We developed an occlusive circumferential wrap dressing technique that reduces skin edge tension, eliminates dead space, and prevents external contamination. We compared the surgical site infection rate using the wrap dressing techniq...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 2003-01, Vol.75 (1), p.101-105 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Infection in the saphenous vein harvest site is a common problem. We developed an occlusive circumferential wrap dressing technique that reduces skin edge tension, eliminates dead space, and prevents external contamination. We compared the surgical site infection rate using the wrap dressing technique with that of standard longitudinal dressings.
One hundred fifty-two consecutive patients were randomly assigned to receive either standard dressings or the wrap dressing. Data were collected in the hospital and then 4 to 6 weeks postoperatively. Superficial and deep wound infections were defined by the standard criteria from the Centers for Disease Control and Prevention.
The infection rate in the wrap group was 14% compared with 35%, for the standard group (p = 0.006). Multivariate analysis showed that wrap technique was the only significant predictor (negative) of infection (odds ratio, 0.19; p = 0.001).
In saphenous vein harvest wounds, the occlusive wrap dressing technique has the potential to reduce the rate of infection by 50%. This simple and inexpensive technique is also readily applicable to the radial artery harvest site in the arm and may provide similar benefit. |
---|---|
ISSN: | 0003-4975 1552-6259 |