INADVERTENT ADMINISTRATION OF PROSTAGLANDIN E1 INSTEAD OF PROSTAGLANDIN F2α IN A PATIENT WITH UTERINE ATONY AND HEMORRHAGE

A woman underwent cesarean delivery for premature labor, breech presentation, and ruptured membranes. Placenta, accreta associated with uterine atony and severe hemorrhage was diagnosed. Prostaglandin E1 instead of prostaglandin F2α was inadvertently administered in an effort to control the hemorrha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Obstetrics and gynecology (New York. 1953) 1992-05, Vol.79 (5, Part 2 Suppl), p.890-893
Hauptverfasser: Reedy, M B, McMillion, J S, Engvall, W R, Sulak, P J, Fisher, N L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A woman underwent cesarean delivery for premature labor, breech presentation, and ruptured membranes. Placenta, accreta associated with uterine atony and severe hemorrhage was diagnosed. Prostaglandin E1 instead of prostaglandin F2α was inadvertently administered in an effort to control the hemorrhage. The resulting complications included profound hypotension, disseminated intravascular coagulation, and ventricular tachycardia.
ISSN:0029-7844
1873-233X