Resistant nonunions and partial or complete segmental defects of long bones : treatment with implants of a composite of human bone morphogenetic protein (BMP) and autolyzed, antigen-extracted, allogeneic (AAA) bone

Twenty-five patients with resistant nonunions including partial or complete segmental defects were treated with a composite alloimplant of human bone morphogenetic protein (h-BMP) and autolyzed, antigen-free, allogeneic bone (AAA). The series consisted of 16 females and nine males; average age was 4...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical orthopaedics and related research 1992-04, Vol.277 (277), p.229-237
Hauptverfasser: JOHNSON, E. E, URIST, M. R, FINERMAN, G. A. M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Twenty-five patients with resistant nonunions including partial or complete segmental defects were treated with a composite alloimplant of human bone morphogenetic protein (h-BMP) and autolyzed, antigen-free, allogeneic bone (AAA). The series consisted of 16 females and nine males; average age was 45 years. Preoperative symptoms averaged 30 months (range, five to 83 months); 22 of 25 patients had failed multiple attempts at electrical stimulation. Twenty-three of 25 patients had an average of three prior failed surgical attempts at union (range, one to ten). There were ten segmental defects with an average length of 4 cm (range, 2-9 cm). The composite implant was incorporated as an onlay in 15 extremities and as an inlay graft supported by internal fixation in ten extremities. Seven patients received supplementary autogeneic cancellous bone grafting. Average healing time was six months (range, three to 14 months). Average follow-up time was 21 months (range, five to 82 months). Functional results were rated as excellent, 14; good, five; and fair, five. One failed to unite because of a recurrent infection. Union was obtained in 24 of 25 patients. There were five failures of the original operation that required reoperations; union eventually occurred in four of five extremities by repeat composite grafting and replacement of the failed internal fixation. Bony union between host bone and the composite implant began at an average of eight weeks postoperatively. Present results indicate that h-BMP/AAA composite implants represent adjunctive treatment of difficult nonunions. The h-BMP/AAA composite implants may be implanted in either partial or complete segmental defects of long bones.
ISSN:0009-921X
1528-1132