Use of a heat exchanger in liver transplantation

Of the first 16 patients who underwent orthoptic liver transplantation, 81 % were observed to be hypothermic at termination of bypass (X = 34.5°C, n = 16). In response, an in-line heat exchangerwas added to the bypass circuit. Subsequently, 72% of the next 11 patients terminated bypass normothermic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Perfusion 1991, Vol.6 (4), p.279-283
Hauptverfasser: Butler, Kevin T, Raskin, Steven A, Whisennand, Hartwell H, Lowell, William R, Gay, Joseph R, Cornelius, Gary F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Of the first 16 patients who underwent orthoptic liver transplantation, 81 % were observed to be hypothermic at termination of bypass (X = 34.5°C, n = 16). In response, an in-line heat exchangerwas added to the bypass circuit. Subsequently, 72% of the next 11 patients terminated bypass normothermic (x = 37.0°C, n = 11). By removing from the sample those patients who incurred low blood flows, 100% of the patients terminated bypass normothermic (X = 38.2°C, n = 8). At temperatures of 30-33°C cardiac arrhythmias have been observed. Hypothermia has been documented to cause thrombocytopenia and neutropenia which can lead to blood loss. These low counts are only partially reversible with platelet infusion and white blood cells (WBC). The use of an in-line heat exchanger during liver transplantation is essential in preventing hypothermia in our experience.
ISSN:0267-6591
1477-111X
DOI:10.1177/026765919100600407