The Carpentier‐Edwards Standard Porcine Bioprosthesis: Clinical Performance to 15 Years

The Carpentier‐Edwards standard porcine bioprosthesis was implanted in 1,195 patients in 1,213 operative procedures between 1975 and 1987, with the majority of implants performed prior to 1982 at the University of British Columbia. The mean age of the patient population was 57.2 years (range 8 to 85...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiac surgery 1991-12, Vol.6 (4S), p.550-556
Hauptverfasser: Jamieson, W.R. Eric, Hayden, Robert I., Miyagishima, Robert T., Tutassaura, Hernando, Munro, A. Ian, Gerein, Alfred N., Burr, Lawrence H., MacNab, Joan, Janusz, Michael T., Chan, Florence, Ling, Hilton, Tyers, G. Frank O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Carpentier‐Edwards standard porcine bioprosthesis was implanted in 1,195 patients in 1,213 operative procedures between 1975 and 1987, with the majority of implants performed prior to 1982 at the University of British Columbia. The mean age of the patient population was 57.2 years (range 8 to 85 years). The mean follow‐up was 7.4 years per patient. The freedom from the combination of thromboemboiism and antithromboembolic therapy‐related hemorrhage at 15 years was 79.5% for aortic valve replacement (AVR), 72% for mitral valve replacement (MVR), and 84% for multiple valve replacement (MR) (p < 0.05, AVR > MR > MVR). The freedom from structural valve deterioration at 15 years was 71% for AVR, 41% for MVR, and 41% for MR (14 years) (p < 0.05, AVR > MVR > MR). The freedom from nonstructural dysfunction and prosthetic valve endocarditis did not distinguish the valve positions (p = NS). The freedom from valve‐related mortality from all causes including reoperation was 92% for AVR, 78% for MVR, and 77% for MR at 15 years (p < 0.05, AVR > MVR > MR). The freedom from residual morbidity was not significantly different between valve positions (p = NS). The freedom from treatment failure (valve‐related mortality and residual morbidity) at 15 years was 87% for AVR, 72% for MVR, and 75% for MR (p < 0.05, AVR > MR > MVR). The freedom from all complications at 14 years was 50% for AVR, 25% for MVR, and 27% for MR (p < 0.05, AVR > MR > MVR). The Carpentier‐Edwards standard porcine bloprosthesis has provided satisfactory clinical performance in a valve replacement population essentially receiving only biological prostheses.
ISSN:0886-0440
1540-8191
DOI:10.1111/jocs.1991.6.4s.550