An Evaluation of the OnTrak Testcup®- er On-Site Urine Drug-Testing Device for Drugs Commonly Encountered from Emergency Departments

We evaluated the performance of the Roche OnTrak Testcup-er (TC-er), an on-site drug-testing device, for the detection of amphetamines (AMP), barbiturates (BRB), benzodiazepines (BNZ), benzoylecgonine (BE), and opiates (OPI) in urine specimens from hospital emergency departments. This device utilize...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical toxicology 2002-10, Vol.26 (7), p.500-503
Hauptverfasser: Peace, Michelle R., Poklis, Justin L., Tarnai, Lisa D., Poklis, Alphonse
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We evaluated the performance of the Roche OnTrak Testcup-er (TC-er), an on-site drug-testing device, for the detection of amphetamines (AMP), barbiturates (BRB), benzodiazepines (BNZ), benzoylecgonine (BE), and opiates (OPI) in urine specimens from hospital emergency departments. This device utilizes a competitive binding microparticle immunoassay to simultaneously determine the presence of the following drugs or drug classes in urine at and above the following cut-off concentrations: AMP, 1000 ng/mL; BRB, 200 ng/mL; BNZ 200 ng/mL; BE, 300 ng/mL; and OPI, 300 ng/mL. One hundred forty-nine urine specimens received from emergency departments were simultaneously tested by the EMIT® II monoclonal immunoassay (Emit) and TC-er. Specimens yielding discordant results were analyzed by gas chromatography-mass spectrometry. There was a 98% (146/149) agreement of results between the methods for the presence or absence of drugs. TC-er yielded 110 positive drug findings in 79 specimens, and Emit yielded 102 positive drug findings in 76 specimens. There was a 97% agreement between the methods for positive findings of at least one drug. The majority of discordant results were due to variations in selectivity of the assays for phenobarbital and BNZ metabolites. TC-er yielded a single false-positive result for amphetamines, and barbiturates, possibly three false-positive benzodiazepine results, and a single false-negative opiate finding. This represented four certain errors out of 745 total results, or a 0.4% error rate. If the three false-positive BNZ results were also considered, the error rate would be 0.9%. TC-er demonstrated acceptable linearity around the cut-off concentration of each drug. The TC-er was determined to be a reliable device for rapid on-site testing of emergency department urine specimens.
ISSN:0146-4760
1945-2403
DOI:10.1093/jat/26.7.500