Improvement of three-dimensional treatment planning models of small lung targets using high-speed multi-slice computed tomographic imaging
Purpose : To improve the reliability of the patient model and reduce treatment volume by acquiring multi-slice computed tomographic (CT) data with the patients’ single holding of breath at normal inhalation and exhalation. Methods and Materials : Seven patients with nine small peripheral lung cancer...
Gespeichert in:
Veröffentlicht in: | International journal of radiation oncology, biology, physics biology, physics, 2002-11, Vol.54 (4), p.1210-1216 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
: To improve the reliability of the patient model and reduce treatment volume by acquiring multi-slice computed tomographic (CT) data with the patients’ single holding of breath at normal inhalation and exhalation.
Methods and Materials
: Seven patients with nine small peripheral lung cancer tumors underwent CT scanning under three respiration conditions using multi-slice CT: free breathing (FB), shallow inspiration (SI), and shallow expiration (SE). To compare the treatment plan created using the two-respiratory-phase images (SI + SE) with the plans created using only SE images or using only FB images, we attempted to calculate the true dosimetric characteristics for three-dimensional treatment planning taking respiratory movement into consideration. Minimum dose to the gross tumor volume (GTV) and ipsilateral lung dose-volume histogram (DVH) were calculated for the inhalation and exhalation positions of shallow breathing.
Results
: There was no significant difference between minimum doses of the GTV in the three treatment plans when using anteroposterior/posteroanterior parallel-opposed fields. However, there was a significant difference between the minimum doses of the GTV in the two-phase treatment plan and the minimum dose in the other treatment plans when using the four-field technique, consisting of shaped anterior, posterior, right and left lateral fields (
p = 0.03, 0.04). Comparison of the percent volume of ipsilateral lung receiving a dose exceeding 20 Gy (V
20) based on inhalation and exhalation CT data revealed that the V
20 of the two-phase plan was the smallest of the three treatment planning fields (
p < 0.001).
Conclusion
: Two-phase planning using multi-slice CT provides an immediate reduction in the amount of normal tissue treated and improved reliability of patient data for DVH modeling. |
---|---|
ISSN: | 0360-3016 1879-355X |
DOI: | 10.1016/S0360-3016(02)03813-0 |