Reproducibility of chronic infarct size measurement by contrast-enhanced magnetic resonance imaging

The reproducibility of contrast-enhanced MRI has not been established. We compared MRI reproducibility for infarct size determination with that of (99m)Tc-sestamibi (MIBI) single photon emission computed tomography (SPECT). Patients with chronic myocardial infarction defined by enzymes (peak creatin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 2002-10, Vol.106 (18), p.2322-2327
Hauptverfasser: Mahrholdt, Heiko, Wagner, Anja, Holly, Thomas A, Elliott, Michael D, Bonow, Robert O, Kim, Raymond J, Judd, Robert M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The reproducibility of contrast-enhanced MRI has not been established. We compared MRI reproducibility for infarct size determination with that of (99m)Tc-sestamibi (MIBI) single photon emission computed tomography (SPECT). Patients with chronic myocardial infarction defined by enzymes (peak creatine kinase-MB 173+/-119 U/L) were scanned twice by MRI (MRI I and MRI II, n=20) and twice by SPECT (SPECT I and SPECT II, n=15) on the same day. The MRI contrast agent was injected during MRI I but not MRI II to test the effect of imaging time after contrast. Resting Tc-MIBI SPECT images were acquired and infarct size was determined with commercial software. Infarct size in patients scanned by MRI and SPECT was 14+/-6% of left ventricular mass (%LV) by MRI (range 4%LV to 27%LV) and 14+/-7%LV by SPECT (range 4%LV to 26%LV). MRI I and II scans were performed 10+/-2 and 27+/-3 minutes after contrast, respectively. For MRI, the difference in infarct size between scans I and II (bias) was -0.1%LV, and the coefficient of repeatability was +/-2.4%LV. For SPECT, bias was -1.3%LV, and the coefficient of repeatability was +/-4.0%LV. Within individual patients, no systematic differences in infarct size were detected when the 2 MRI scans were compared, the 2 SPECT scans were compared, or MRI was compared to SPECT. The size of healed infarcts measured by contrast-enhanced MRI does not change between 10 and 30 minutes after contrast. The clinical reproducibility of contrast-enhanced MRI for infarct size determination compares favorably with that of routine clinical SPECT.
ISSN:0009-7322
1524-4539
DOI:10.1161/01.CIR.0000036368.63317.1C