Microbial population in a hydrogen-dependent denitrification reactor
The bacterial population in an H 2-dependent denitrification system was studied. The laboratory set-up was designed for the treatment of potable water and consisted of an electrochemical cell, where the water to be treated was enriched with H 2 prior to entering a bioreactor. Bioreactors (columns pa...
Gespeichert in:
Veröffentlicht in: | Water research (Oxford) 2002-09, Vol.36 (16), p.4088-4094 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The bacterial population in an H
2-dependent denitrification system was studied. The laboratory set-up was designed for the treatment of potable water and consisted of an electrochemical cell, where the water to be treated was enriched with H
2 prior to entering a bioreactor. Bioreactors (columns packed with granulated active carbon) were inoculated with denitrifying bacterial strains isolated from a previous reactor, then sampled immediately after inoculation, or after 1 or 3 months of continuous operation. Total number of the bacteria and numbers of each different strain were determined at various levels of the bioreactor. The strains present in the inoculum were identified as
Ochrobactrum anthropi,
Pseudomonas stutzeri,
Paracoccus panthotrophus and
Paracoccus denitrificans. Numbers of the latter declined markedly with time with the other three strains being responsible for nitrate removal. A correlation was found between the relative abundance of each strain and its specific denitrification activity. |
---|---|
ISSN: | 0043-1354 1879-2448 |
DOI: | 10.1016/S0043-1354(02)00130-6 |