A combined intra- and extra-articular reconstruction using a carbon-dacron composite prosthesis for chronic anterior cruciate instability. A two to six-year follow-up study
Fifty patients with chronic symptomatic anterior cruciate insufficiency underwent ligamentous reconstruction using the "Westminster Composite Prosthesis" which consists of a central core of carbon fibre with an external weave of polyester. In 42 patients, the prosthesis was used as an augm...
Gespeichert in:
Veröffentlicht in: | International orthopaedics 1991-09, Vol.15 (3), p.219-227 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Fifty patients with chronic symptomatic anterior cruciate insufficiency underwent ligamentous reconstruction using the "Westminster Composite Prosthesis" which consists of a central core of carbon fibre with an external weave of polyester. In 42 patients, the prosthesis was used as an augmentation within a tube of ilio-tibial tract, combined with a MacIntosh's extraarticular reconstruction. The prosthetic replacement alone was used in eight patients where there had been a previous extraarticular reconstruction and was associated with only fair results. The average age of the patients at operation was 28.5 years (range 18 to 50 years); instability of the knee had been present for a mean of 5.3 years and the average follow-up was 3.8 years (range 2 to 6 years). Assessment included subjective functional rating (Lysholm knee score) and clinical examination for instability. Thirty-seven patients (74%) had a good or excellent result, 11 (22%) had a fair result and two (4%) had a poor result. The Lachman test was grade I or less in 35 patients and the pivot shift sign was eliminated in 37 patients. Clinical signs of instability correlated well with the Lysholm knee score (p less than 0.001). Twenty-two unselected patients (44%) underwent an arthroscopic assessment and biopsy of the "neoligament" at an average of 10.4 months post-operatively. The prosthesis was found to be stable and well covered by a thick fibrous sheath ("neoligament") in 19 patients. The prosthesis was partially ruptured in two patients and completely disrupted in one. Thirty-two patients (64%) returned to their previous sports and 13 of them (26%) achieved their pre-injury level of performance. |
---|---|
ISSN: | 0341-2695 1432-5195 |
DOI: | 10.1007/BF00192298 |