Effect of furnace type and ceramming heat treatment conditions on the biaxial flexural strength of a canasite glass-ceramic
Objective: To assess the effect of different heat treatment conditions when using two different furnace types on the biaxial flexural strength (BFS) of a fluorcanasite castable glass-ceramic. Methods: Two furnace types, one a programmable furnace (PF), the other a dental laboratory burnout furnace (...
Gespeichert in:
Veröffentlicht in: | Dental materials 2000-07, Vol.16 (4), p.280-284 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective: To assess the effect of different heat treatment conditions when using two different furnace types on the biaxial flexural strength (BFS) of a fluorcanasite castable glass-ceramic.
Methods: Two furnace types, one a programmable furnace (PF), the other a dental laboratory burnout furnace (DLF), were used with various ceramming times to determine their effect on the BFS of a fluorcanasite castable glass-ceramic. The glass-ceramic material was cast to produce discs of 12
mm diameter and 2
mm thickness using the lost wax casting process
(n=80). After casting, both furnace types were used to ceram the discs. Half the discs were not de-vested from the casting ring before ceramming but cerammed in situ (DLF) and half were de-vested before ceramming (PF). All the discs were given a nucleation heat treatment at 520°C for 1
h and then cerammed at 860°C using four heat soak times (0.5, 1, 2 and 3
h). The DLF furnace had a rate of climb of 13°C /min and the PF furnace had a rate of climb of 5°C /min to 520°C and 3°C /min to 860°C. After ceramming the discs were de-vested and the BFS determined using a Lloyd 2000R tester.
Results: The maximum BFS values seen for both furnace types were almost identical (280
MPa), but were achieved at different heat soak times (1
h DLF, and 2
h PF). The only significant differences in BFS values for the two furnaces were between the 0.5 and 2
h heat soak times
(p≤0.05). Individual differences were seen between results obtained from each furnace type/heat soak times evaluated
(p≤0.05).
Significance: Already available dental laboratory burnout furnaces can be used to ceram fluorcanasite glass-ceramic castings to the same BFS values as more expensive and slower specialist programmable furnaces. |
---|---|