Ultimate limits in ultrasonic imaging resolution

According to elementary theory, the resolution of an ultrasonic imaging system increases with the ultrasonic frequency. However, frequency is limited by frequency-dependent attenuation. For imaging at any required depth, resolution improvement beyond the limit imposed by ultrasonic frequency can be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasound in Medicine & Biology 1991, Vol.17 (6), p.547-558
Hauptverfasser: Harris, R.A., Follett, D.H., Halliwell, M., Wells, P.N.T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:According to elementary theory, the resolution of an ultrasonic imaging system increases with the ultrasonic frequency. However, frequency is limited by frequency-dependent attenuation. For imaging at any required depth, resolution improvement beyond the limit imposed by ultrasonic frequency can be obtained by increasing the ultrasonic intensity. This is itself, however, dependent on safety considerations and the effects of nonlinearity. In homogeneous media, image resolution increases with decreasing f-number. Particularly at low f-numbers, however, tissue inhomogeneity leads to a deterioration in image quality. Inhomogeneity may also be considered in terms of phase aberration. It has been found that for a given aperture, image degradation due to phase aberration is worse at higher frequencies. Schemes have been proposed for correction of this problem, but so far model systems do not lend themselves to clinical application. Deconvolution is unsatisfactory, speed correction is impracticable and synthetic aperture scanning and holography are virtually useless in biological tissues. Ultra-sound-computed tomography has had only limited success. Speckle reduction can improve target detectability, but at the expense of resolution. Time-frequency control provides a useful partial solution to the problem of resolution reduction resulting from attenuation. It is clear that improved resolution would result in significant clinical benefits. An optimisation system for aperture size and ultrasonic frequency is proposed with signal averaging for resolution enhancement of a defined object area. This would have a compact ultrasonic beam and would allow frame rate to be traded for resolution, by means of signal averaging.
ISSN:0301-5629
1879-291X
DOI:10.1016/0301-5629(91)90025-R