Delayed posterior dislocation of silicone plate-haptic lenses after neodymium:yag capsulotomy

We report 4 cases of posterior dislocation of silicone plate-haptic intraocular lenses (iols) into the vitreous cavity occurring a mean of 16 months after neodymium:YAG laser posterior capsulotomy. In each case, no peripheral capsule defect was observed at the time of laser capsulotomy or at subsequ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cataract and refractive surgery 2000-12, Vol.26 (12), p.1827-1829
Hauptverfasser: Petersen, Aaron M, Bluth, L.Lothaire, Campion, Michael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report 4 cases of posterior dislocation of silicone plate-haptic intraocular lenses (iols) into the vitreous cavity occurring a mean of 16 months after neodymium:YAG laser posterior capsulotomy. In each case, no peripheral capsule defect was observed at the time of laser capsulotomy or at subsequent follow-ups. One case was treated with sulcus implantation of a 3-piece IOL, with the plate-haptic IOL left in the vitreous cavity. The other cases were managed with vitrectomy (2 pars plana, 1 anterior) to remove the plate-haptic lens with subsequent sulcus placement of a 3-piece IOL. Patients should be informed that posterior dislocation is an infrequent but possible complication of these lenses and may occur months and even years after implantation or laser capsulotomy.
ISSN:0886-3350
1873-4502
DOI:10.1016/S0886-3350(00)00500-9