Treatment of a saphenous vein graft to right ventricle fistula with a PTFE-covered stent: A case report

This report demonstrates the use of a covered stent for the correction of a fistula from a saphenous vein graft to the right ventricle. The use of this stent resulted in complete obliteration of the fistulous tract and restoration of flow into the sequential limb of the graft. Cathet Cardiovasc Inte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2001-12, Vol.54 (4), p.531-532
Hauptverfasser: Smith, Robert W., Schussler, Jeffrey M., Anwar, Azam, Donsky, Michael S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This report demonstrates the use of a covered stent for the correction of a fistula from a saphenous vein graft to the right ventricle. The use of this stent resulted in complete obliteration of the fistulous tract and restoration of flow into the sequential limb of the graft. Cathet Cardiovasc Intervent 2001;54:531–532. © 2001 Wiley‐Liss, Inc.
ISSN:1522-1946
1522-726X
DOI:10.1002/ccd.1327