Sternal closure with resorbable synthetic loop suture material in children
Purpose: The reliability of poly-p-dioxanone (PDS) suture for sternal closure was tested on 264 consecutive sternotomies in the authors' department from April 1987 to May 1998. Methods: The reason for sternotomy was tetralogy of Fallot in 65 cases (24.6%), ventricular septal defect (VSD) in 38...
Gespeichert in:
Veröffentlicht in: | Journal of pediatric surgery 2000-09, Vol.35 (9), p.1309-1311 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: The reliability of poly-p-dioxanone (PDS) suture for sternal closure was tested on 264 consecutive sternotomies in the authors' department from April 1987 to May 1998. Methods: The reason for sternotomy was tetralogy of Fallot in 65 cases (24.6%), ventricular septal defect (VSD) in 38 cases (14.4%), atrial septal defect (ASD) in 77 cases (29.2%), ASD + VSD in 23 (8.7%), mitral valve replacement in 22 cases (8.3%), aortic valve replacement in 10 cases (3.8%), and other cardiac disorders in 29 cases (11.0%). Results: Sternal wound infection, sternal dehiscence, and mediastinitis occurred in 1.5% of patients (4 of 264). The overall hospital mortality rate related to the mediastinitis was 1.1% (3 of 264) in the early postoperative period. Conclusion: This absorbable suture and our different technique are a safe alternative to standard sternotomy closure after pediatric open cardiac surgery. J Pediatr Surg 35:1309-1311. Copyright © 2000 by W.B. Saunders Company. |
---|---|
ISSN: | 0022-3468 1531-5037 |
DOI: | 10.1053/jpsu.2000.9311 |