A comparison of two methods to perform a breathing trial before extubation in pediatric intensive care patients
To compare the percentage of infants and children successfully extubated after a trial of breathing performed with either pressure support or T-piece. Prospective and randomized study. Three medical-surgical pediatric intensive care units (PICUs). Two hundred fifty-seven consecutive infants and chil...
Gespeichert in:
Veröffentlicht in: | Intensive care medicine 2001-10, Vol.27 (10), p.1649-1654 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To compare the percentage of infants and children successfully extubated after a trial of breathing performed with either pressure support or T-piece.
Prospective and randomized study.
Three medical-surgical pediatric intensive care units (PICUs).
Two hundred fifty-seven consecutive infants and children who received mechanical ventilation for at least 48 h and were deemed ready to undergo a breathing trial by their primary physician.
Patients were randomly assigned to undergo a trial of breathing in one of two ways: pressure support of 10 cmH2O or T-piece. Bedside measurements of respiratory function were obtained immediately before discontinuation of mechanical ventilation and within the first 5 min of breathing through a T-piece. The primary physicians were unaware of those measurements, and the decision to extubate a patient at the end of the breathing trial was made by them.
Of the 125 patients in the pressure support group, 99 (79.2%) completed the breathing trial and were extubated, but 15 of them (15.1%) required reintubation within 48 h. Of the 132 patients in the T-piece group, 102 (77.5%) completed the breathing trial and were extubated, but 13 of them (12.7%) required reintubation within 48 h. The percentage of patients who remained extubated for 48 h after the breathing trial did not differ in the pressure support and T-piece groups (67.2% versus 67.4%, p=0.97).
In infants and children mechanically ventilated, successful extubation was achieved equally effectively after a first breathing trial performed with pressure support of 10 cmH2O or a T-piece. |
---|---|