Determination of Total Interleukin-8 in Whole Blood after Cell Lysis

It has been shown that a high percentage of interleukin-8 (IL-8) in blood is cell associated. Recently, a simple method for determination of cell-associated IL-8 in whole blood after cell lysis has been described. The purpose of this study was to evaluate this method, to examine the influence of pre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry (Baltimore, Md.) Md.), 2000-09, Vol.46 (9), p.1387-1394
Hauptverfasser: Reinsberg, Jochen, Dembinski, Jorg, Dorn, Christoph, Behrendt, Daniela, Bartmann, Peter, van der Ven, Hans
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:It has been shown that a high percentage of interleukin-8 (IL-8) in blood is cell associated. Recently, a simple method for determination of cell-associated IL-8 in whole blood after cell lysis has been described. The purpose of this study was to evaluate this method, to examine the influence of preanalytic sample handling, and to establish the concentration range of total IL-8 and its relation to age and sex in healthy subjects. Total IL-8 content of whole blood was determined after lysing blood cells with Milenia((R)) cell lysis solution. IL-8 in the resulting blood lysate was measured with the IMMULITE((R)) IL-8 immunoassay. When freshly drawn blood was stored up to 48 h on ice, no significant changes in total IL-8 were measured in the subsequently prepared lysate, whereas with storage at room temperature, total IL-8 increased after 3 h from 94 +/- 13 ng/L to 114 +/- 16 ng/L (n = 10). In lysate stored for 48 h at 4 degrees C, marginal changes of the IL-8 concentration were noted, with storage at room temperature, only 76% +/- 5% (n = 12) of initial concentration was recovered. From lysate frozen at -20 and -80 degrees C, respectively, 84% +/- 4% and 93% +/- 2% of initial IL-8 was recovered after 70 days (n = 10). IL-8 was measured with comparable precision in plasma (CV, 3. 2-4.2%) and blood lysate (CV, 3.7-4.1%). When plasma was diluted with cell lysis solution, a slightly overestimated recovery (125% +/- 3%) was observed; for lysate specimens with a cell lysis solution content >/=75%, the recovery after dilution was 98% +/- 2%. In lysate prepared from 12 blood samples with exogenous IL-8 added, IL-8 recovery was 104% +/- 2% (recovery from plasma
ISSN:0009-9147
1530-8561