Screw migration from total knee prostheses requiring subsequent surgery
Complications in total knee arthroplasty directly related to hardware failure other than polyethylene wear are rare. We report 2 cases of symptomatic screw migration into the joint space from total knee prostheses. In the first case, a screw disengaged from a constrained condylar knee prosthesis. Ar...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2002-10, Vol.17 (7), p.951-954 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Complications in total knee arthroplasty directly related to hardware failure other than polyethylene wear are rare. We report 2 cases of symptomatic screw migration into the joint space from total knee prostheses. In the first case, a screw disengaged from a constrained condylar knee prosthesis. Arthroscopy using standard arthroscopy portals and a small arthrotomy were performed to remove the screw. In the second case, symptomatic screw disengagement and posterior migration from the tibial component of a posterior-stabilized prosthesis occurred. Revision with replacement of the polyethylene insert and locking screw was required. Copyright 2002, Elsevier Science (USA). All rights reserved. |
---|---|