Removal of a laryngeal foreign body using high frequency jet ventilation

Summary Aspiration of a foreign body into the respiratory tract is a common and serious accident in childhood. Laryngotracheal foreign bodies, although less common than bronchial foreign bodies, are potentially more dangerous. Removal is commonly achieved using a rigid ventilating bronchoscope. We r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anaesthesia 1991-09, Vol.46 (9), p.741-743
Hauptverfasser: TAN, S. S., DHARA, S. S., SIM, C. K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary Aspiration of a foreign body into the respiratory tract is a common and serious accident in childhood. Laryngotracheal foreign bodies, although less common than bronchial foreign bodies, are potentially more dangerous. Removal is commonly achieved using a rigid ventilating bronchoscope. We report a 16‐month‐old boy who had an open safety pin impacted in his larynx. This was removed through a tracheostomy, using high frequency jet ventilation to maintain gaseous exchange. We believe that this is the first case in which this method of removal has been reported.
ISSN:0003-2409
1365-2044