Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: A cautionary note
Background: Positional stability of the endograft is essential for long-term durability after endovascular abdominal aortic aneurysm repair (EAR). However, the cumulative risk of delayed endograft migration has been sparsely reported. Method: A total of 91 patients studied underwent EAR with the Ane...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery 2002-09, Vol.36 (3), p.476-484 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: Positional stability of the endograft is essential for long-term durability after endovascular abdominal aortic aneurysm repair (EAR). However, the cumulative risk of delayed endograft migration has been sparsely reported.
Method: A total of 91 patients studied underwent EAR with the AneuRx endograft with a minimum 1 year from implantation. Data from a prospective database were assessed for proximal endograft migration, defined as ≥5 mm change from the initial endograft position. Multiple anatomic characteristics were also examined. Sixty-nine patients were alive, with complete follow-up at 1 year, with a mean time from implantation of 33.2 ± 1.1 months. Data are mean ± SEM.
Results: Endograft migration occurred in 15 patients, giving a cumulative event rate of 7.2% (5/69) at 1 year, 20.4% (10/49) at 2 years, 42.1% (8/19) at 3 years, and 66.7% (2/3) at 4 years post-EAR (
P = .01). Although the initial aortic neck diameter did not differ between the groups (21.5 ± 0.6 mm vs 21.8 ± 0.3 mm,
P = .61), significant (
P 20% and 18.6% in patients oversized ≤20%. Aortic neck angulation (23.4 ± 6.6 degrees vs 23.5 ± 3.3 degrees,
P = .99), aortic neck length (25.9 ± 2.5 mm vs 27.0 ± 1.6 mm,
P = .74), initial endograft/aortic neck overlap (18.6 ± 2.6 mm vs 19.4 ± 1.4 mm,
P = .80) and size of abdominal aortic aneurysm (55.5 ± 1.5 mm vs 54.9 ± 1.4 mm,
P = .84) were similar between migrators and nonmigrators, respectively. Secondary endovascular treatment with aortic cuffs was required in five patients with device migration.
Conclusions: Device migration after EAR with the AneuRx endograft occurred with significant frequency, the incidence of which increased with the length of follow-up. Late aortic neck dilation was significantly associated with migration. Oversizing of the endograft of >20% may accelerate this late aortic neck dilation. However, the etiologies of endograft migration were likely multifactorial, as the majority (8/15) of patients experiencing migration were oversized |
---|---|