Bispectral index in patients with target-controlled or manually-controlled infusion of propofol
In this prospective, randomized study we compared bispectral index (BIS), hemodynamics, time to extubation, and the costs of target-controlled infusion (TCI) and manually-controlled infusion (MCI) of propofol. Forty patients undergoing first-time implantation of a cardioverter-defibrillator were inc...
Gespeichert in:
Veröffentlicht in: | Anesthesia and analgesia 2002-09, Vol.95 (3), p.639-644 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this prospective, randomized study we compared bispectral index (BIS), hemodynamics, time to extubation, and the costs of target-controlled infusion (TCI) and manually-controlled infusion (MCI) of propofol. Forty patients undergoing first-time implantation of a cardioverter-defibrillator were included. Anesthesia was performed with remifentanil (0.2-0.3 micro g. kg(-1). min(-1)) and propofol. Propofol was used as TCI (plasma target concentration, 2.5-3.5 micro g/mL; n = 20) or MCI (3.0-4.0 mg. kg(-1). h(-1); n = 20). BIS, heart rate, and arterial blood pressure were measured at six data points: T1, before anesthesia; T2, after intubation; T3, after skin incision; T4, after first defibrillation; T5, after third defibrillation; and T6, after extubation. There were no significant hemodynamic differences between the two groups. BIS was significantly lower at T3 and T4 in the TCI group than in the MCI group. The mean dose of propofol was larger in TCI patients (5.8 +/- 1.4 mg. kg(-1). h(-1)) than in the MCI patients (3.7 +/- 0.6 mg. kg(-1). h(-1)) (P < 0.05), whereas doses of remifentanil did not differ. Time to extubation did not differ between the two groups (TCI, 13.7 +/- 5.3 min; MCI, 12.3 +/- 3.5 min). One patient in the MCI group had signs of intraoperative awareness without explicit memory after first defibrillation (BIS before shock, 49; after shock, 83). Costs were significantly less in the MCI group (34.83 US dollars) than in the TCI group (39.73 US dollars). BIS failed to predict the adequacy of anesthesia for the next painful stimulus.
In this prospective, randomized study, bispectral index (BIS), hemodynamics, time to extubation, and costs of target-controlled infusion (TCI) and manually-controlled infusion of propofol were compared. TCI increased the amount of propofol used. BIS failed to predict the adequacy of anesthesia for the next painful stimulus. |
---|---|
ISSN: | 0003-2999 1526-7598 |
DOI: | 10.1097/00000539-200209000-00027 |