We describe here a case of accidental electrocution. A 48-year-old male was found dead in his room. At autopsy, there was a current mark on the right thumb and big toe. Histological examination revealed that the skin wound had the characteristics of a current mark, including vacuolation and elongati...
Gespeichert in:
Veröffentlicht in: | Legal medicine (Tokyo, Japan) Japan), 2004-03, Vol.6 (1), p.55-60 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We describe here a case of accidental electrocution. A 48-year-old male was found dead in his room. At autopsy, there was a current mark on the right thumb and big toe. Histological examination revealed that the skin wound had the characteristics of a current mark, including vacuolation and elongation of the cell nuclei. We could also identify titanium metallization on the skin surface of the current mark using a variable-pressure scanning electron microscope (VP-SEM) equipped with energy dispersive X-ray microanalyser (EDX). The autopsy finding and the subsequent investigation support the conclusion that the cause of his death was electrocution. Our result shows that the VP-SEM with EDX is a useful tool for the forensic diagnosis of electrocution. |
---|---|