The application of a variable-pressure scanning electron microscope with energy dispersive X-ray microanalyser to the diagnosis of electrocution: a case report

We describe here a case of accidental electrocution. A 48-year-old male was found dead in his room. At autopsy, there was a current mark on the right thumb and big toe. Histological examination revealed that the skin wound had the characteristics of a current mark, including vacuolation and elongati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Legal medicine (Tokyo, Japan) Japan), 2004-03, Vol.6 (1), p.55-60
Hauptverfasser: Kinoshita, Hiroshi, Nishiguchi, Minori, Ouchi, Harumi, Minami, Takako, Kubota, Akira, Utsumi, Takao, Sakamoto, Nobuharu, Kashiwagi, Nobuyuki, Shinomiya, Kouji, Tsuboi, Hideki, Hishida, Shigeru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe here a case of accidental electrocution. A 48-year-old male was found dead in his room. At autopsy, there was a current mark on the right thumb and big toe. Histological examination revealed that the skin wound had the characteristics of a current mark, including vacuolation and elongation of the cell nuclei. We could also identify titanium metallization on the skin surface of the current mark using a variable-pressure scanning electron microscope (VP-SEM) equipped with energy dispersive X-ray microanalyser (EDX). The autopsy finding and the subsequent investigation support the conclusion that the cause of his death was electrocution. Our result shows that the VP-SEM with EDX is a useful tool for the forensic diagnosis of electrocution.