The optimal stack spacing for thermoacoustic refrigeration

The characteristic pore dimension in the stack is an important parameter in the design of thermoacoustic refrigerators. A quantitative experimental investigation into the effect of the pore dimensions on the performance of thermoacoustic devices is reported. Parallel-plate stacks with a plate spacin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2002-07, Vol.112 (1), p.128-133
Hauptverfasser: Tijani, M E H, Zeegers, J C H, de Waele, A T A M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The characteristic pore dimension in the stack is an important parameter in the design of thermoacoustic refrigerators. A quantitative experimental investigation into the effect of the pore dimensions on the performance of thermoacoustic devices is reported. Parallel-plate stacks with a plate spacing varying between 0.15 and 0.7 mm are manufactured and measured. The performance measurements show that a plate spacing in the stack of 0.25 mm (2.5 deltak) is optimum for the cooling power. A spacing of 0.4 mm (4 deltak) leads to the lowest temperature. The optimum spacing for the performance is about 0.3 mm (3 deltak). It is concluded that a plate spacing in the stack of about three times the penetration depth should be optimal (3 deltak) for thermoacoustic refrigeration.
ISSN:0001-4966
1520-8524
DOI:10.1121/1.1487842