Noninvasive assessment of ejection intraventricular pressure gradients

The study was designed to validate in vivo a new method to measure ejection intraventricular pressure gradients (IVPGs) by processing color M-mode Doppler data and to assess the effects of inotropic interventions on IVPGs in the clinical setting. In the absence of obstruction, ejection IVPGs cannot...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 2004-05, Vol.43 (9), p.1654-1662
Hauptverfasser: Yotti, Raquel, Bermejo, Javier, Antoranz, J.Carlos, Rojo-Álvarez, José Luis, Allue, Carmen, Silva, Jacobo, Desco, M.Mar, Moreno, Mar, Garcı́a-Fernández, Miguel A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The study was designed to validate in vivo a new method to measure ejection intraventricular pressure gradients (IVPGs) by processing color M-mode Doppler data and to assess the effects of inotropic interventions on IVPGs in the clinical setting. In the absence of obstruction, ejection IVPGs cannot be estimated by Doppler using the simplified Bernoulli equation. High-fidelity micromanometers were placed in the left ventricle of eight minipigs, and synchronic Doppler images and pressure signals were obtained during different hemodynamic conditions. Twenty healthy volunteers and 20 dilated cardiomyopathy patients were studied at baseline and during esmolol, dobutamine, and atropine infusion (only dobutamine in patients). Excellent agreement was observed between micromanometer and Doppler methods for measuring instantaneous pressure differences among the apex, the mid-cavity, and the outflow tract (Rintraclass= 0.98, 0.81, 0.76, and 0.98 for the peak, time-to-peak, peak reverse, and time-to-peak reverse values, respectively; n = 810 beats). Error of the noninvasive method was −0.05 ± 0.25 mm Hg for the peak pressure difference. Parametrical images demonstrated that IVPGs originate mainly in the mid-ventricle and then propagate to the outflow tract. Both the magnitude and the temporal course of IVPGs were different among volunteers and patients. Inotropic interventions induced significant changes in the apex-outflow tract pressure differences in both populations, whereas atropine had no effect on IVPGs. For the first time, ejection IVPGs can be accurately visualized and measured by Doppler-echocardiography. Important aspects of the dynamic interaction among myocardial performance, load mechanics, and ejection dynamics can be assessed in the clinical setting using this method.
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2003.09.066