Validation of a gas chromatographic method for determination of fatty alcohols in 10 mg film-coated tablets of policosanol

A gas chromatographic method using a packed column and 1-eicosanol as an internal standard was validated for the determination of the fatty alcohols that compose policosanol in 10 mg film-coated tablets. The alcohols were determined as trimethylsilyl derivatives, prepared with N-methyl-N-trimethylsi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of AOAC International 2002-05, Vol.85 (3), p.563-566
Hauptverfasser: SIERRA, Roxana, GONZALEZ, Victor L, MAGRANER, Juan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A gas chromatographic method using a packed column and 1-eicosanol as an internal standard was validated for the determination of the fatty alcohols that compose policosanol in 10 mg film-coated tablets. The alcohols were determined as trimethylsilyl derivatives, prepared with N-methyl-N-trimethylsilyltrifluoroacetamide. The method can detect degradation products with high retention times, without interfering with the peaks of the active principle. Good linearity (correlation coefficient = 0.9992) and accuracy (mean recovery -100.27 +/- 1.66%) were proven over a range of 25-200% of the nominal concentration. Within- and between-day precision at the nominal 100% value met the acceptance criteria (
ISSN:1060-3271
1944-7922