Suction dressings to secure a dermal substitute

One of the problems with the dermal substitute Integra has been securing the material to the wound bed to prevent shearing and loss. Techniques to achieve stability include staples and elastic netting with an over layer of absorbent dressings that can be changed regularly. We report an effective tec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Burns 2004-05, Vol.30 (3), p.259-261
Hauptverfasser: McEwan, Winston, Brown, Tim La H, Mills, Stephen M, Muller, Michael J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:One of the problems with the dermal substitute Integra has been securing the material to the wound bed to prevent shearing and loss. Techniques to achieve stability include staples and elastic netting with an over layer of absorbent dressings that can be changed regularly. We report an effective technique using suction dressings to immobilise Integra. This technique led to firm application underlying tissue, and appeared to decrease fluid collection under the Integra. Earlier mobilisation and discharge from hospital were facilitated.
ISSN:0305-4179
1879-1409
DOI:10.1016/j.burns.2003.11.011