Enhanced separation of filamentous fungi by ultrasonic field: possible usage in repeated batch processes
Usage of ultrasonic field-based filters in retention of filamentous fungal cells was assessed using Rhizopus arrhizus NRRL 1526 as a model organism. Effects of operating conditions, such as power input, harvest pump flow rate, run time and stop time, on the system's separation efficiency (SE) w...
Gespeichert in:
Veröffentlicht in: | Journal of biotechnology 2002-08, Vol.97 (2), p.191-197 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Usage of ultrasonic field-based filters in retention of filamentous fungal cells was assessed using
Rhizopus arrhizus NRRL 1526 as a model organism. Effects of operating conditions, such as power input, harvest pump flow rate, run time and stop time, on the system's separation efficiency (SE) were evaluated by modulating the variables according to a Central Composite Design (CCD). The standard pump with which the ultrasonic filter was equipped was shown to be unsuitable and was, therefore, substituted for with a prime rate reverse pump that made possible separation and recycle of the mycelial biomass. The operating conditions were optimised (run time, 300 s; stop time, 3 s; power input, 6 W; harvest pump flow rate, 4 l per day) and a repeated batch process (three batches for a total of 192 h) was performed during which the SE was maintained always higher than 88%. |
---|---|
ISSN: | 0168-1656 1873-4863 |
DOI: | 10.1016/S0168-1656(02)00062-7 |