Reproducibility of pulsed Doppler measurements of the maternal renal circulation in normal pregnancies and those with pregnancy‐induced hypertension

Objective To assess the inter‐ and intraobserver reproducibilities of pulsed Doppler measurements of the maternal renal circulation in normal pregnancies and those affected by pregnancy‐induced hypertension. Materials and methods Color and pulsed Doppler ultrasound was used to measure acceleration t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasound in obstetrics & gynecology 2002-06, Vol.19 (6), p.598-604
Hauptverfasser: Nakai, A., Miyake, H., Oya, A., Asakura, H., Koshino, T., Araki, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective To assess the inter‐ and intraobserver reproducibilities of pulsed Doppler measurements of the maternal renal circulation in normal pregnancies and those affected by pregnancy‐induced hypertension. Materials and methods Color and pulsed Doppler ultrasound was used to measure acceleration time and resistance index in the renal segmental and interlobar arteries. For the investigation of interobserver reproducibility, two sonographers performed measurements blindly in six normal pregnant women and 14 women with pregnancy‐induced hypertension between 28 and 36 weeks' gestation. A second group of 10 patients between 30 and 35 weeks' gestation were examined by one sonographer to assess the level of intraobserver reproducibility of measurements. For each patient in this group, the flow waveform was measured three times in succession. Calculations of the intraclass correlation coefficient Ri were used to determine the level of reproducibility. Results The interobserver Ri and intraobserver Ri for acceleration time in the segmental artery were 0.95 and 0.96 and for the interlobar artery they were 0.97 and 0.98, respectively. For the resistance index, these values were 0.01 and 0.01 in the segmental artery and 0.52 and 0.29 in the interlobar artery. Conclusion Both the inter‐ and intraobserver reproducibility of acceleration time measurements in the renal segmental and interlobar arteries were clinically acceptable but the equivalent reproducibilities of resistance index measurements were poor. Copyright © 2002 ISUOG
ISSN:0960-7692
1469-0705
DOI:10.1046/j.1469-0705.2002.00638.x