The use of carbon paste electrode in the direct voltammetric determination of tryptophan in pharmaceutical formulations
A simple, fast and sensitive method is proposed for Tryptophan (Trp) determination in pharmaceutical formulations containing other non-electroative aminoacids, vitamins and hydroxycobalamines. Optimized conditions for differential pulse voltammetry allowed the determination of Trp with detection lim...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2002-06, Vol.28 (5), p.909-915 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple, fast and sensitive method is proposed for Tryptophan (Trp) determination in pharmaceutical formulations containing other non-electroative aminoacids, vitamins and hydroxycobalamines. Optimized conditions for differential pulse voltammetry allowed the determination of Trp with detection limit of 1.7 μM in 2–30 mM linear dynamic range (
n=7;
r=0.999), at a bare, non-treated carbon paste electrode. Ascorbic acid interference was evaluated and eliminated by choosing a suitable baseline for determination of peak currents for Trp. |
---|---|
ISSN: | 0731-7085 1873-264X |