Apparent viscoelastic anisotropy as measured from nondestructive oscillatory tests can reflect the presence of a flaw in cortical bone

There is evidence that damage, viscoelastic stiffness properties, and postyield mechanical properties are related in bone tissue. Our objective was to test whether presence of a flaw would have an influence on the apparent viscoelastic properties of bone. Examining the effect of flaw orientation on...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical materials research 2004-04, Vol.69A (1), p.124-130
Hauptverfasser: Yeni, Yener N., Christopherson, Gregory T., Turner, A. Simon, Les, Clifford M., Fyhrie, David P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There is evidence that damage, viscoelastic stiffness properties, and postyield mechanical properties are related in bone tissue. Our objective was to test whether presence of a flaw would have an influence on the apparent viscoelastic properties of bone. Examining the effect of flaw orientation on apparent viscoelastic properties and utilization of dynamic mechanical analysis (DMA) as a nondestructive means for detection of damage were our secondary objectives. Cortical bone beams (2 × 2 × 19 mm) machined from the cranial cortex of the radii of six Warhill sheep were used. The specimens were placed in a DMA machine and baseline measurements of storage modulus (E1) and loss factor (tan δ), once for loads in the craniocaudal and once in the mediolateral directions, were performed using a three‐point bending configuration for a frequency range of 1–10 Hz. Craniocaudal/mediolateral measurement ratio was calculated as a measure of anisotropy for tan δ and E1. After cutting a thin through‐thickness macroscopic notch on the caudal surface at the center of each beam, oscillatory tests were repeated. Two‐way repeated measures analysis of variance followed by Tukey's test was used with group (craniocaudal, mediolateral, notched craniocaudal, and notched mediolateral measurements) and frequency as factors. Regression analysis and analysis of covariance were used for examining the relationship between viscoelastic parameters and frequency. Tan δ and E1 were not different between craniocaudal and mediolateral measurements before the flaw was introduced (p > 0.8 and p = 1, respectively). In the presence of the flaw, tan δ was significantly increased (p < 0.003) whereas E1 was significantly reduced (p < 0.001) for craniocaudal measurements. Tan δ and E1 were nearly isotropic in the tested directions before the introduction of a flaw into the bone tissue. Introduction of a flaw resulted in increased tan δ and E1 anisotropy. Presence of a notch resulted in a significant increase in tan δ anisotropy with increasing frequency. In conclusion, we have demonstrated that cortical bone tissue exhibits a different apparent viscoelastic behavior in the presence of a flaw and depending on the flaw's orientation. Our finding that the presence of a notch and its orientation can be detected by nondestructive DMA suggests that in vivo techniques may be developed for detection of cortical bone damage. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 69A: 124–130, 2004
ISSN:1549-3296
0021-9304
1552-4965
1097-4636
DOI:10.1002/jbm.a.20128