The healing of 62 cases of radial and tibial fractures treated with low‐stiffness Kirschner‐Ehmer external skeletal fixation frames (frame types 1a, 1a plus intramedullary pin [1aIMP], 1b and 2b) was evaluated. The mean time to clinical union was 65 days. All cases treated with 1b, 2b or 1aIMP frame...
Gespeichert in:
Veröffentlicht in: | Journal of small animal practice 2004-02, Vol.45 (2), p.85-91 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The healing of 62 cases of radial and tibial fractures treated with low‐stiffness Kirschner‐Ehmer external skeletal fixation frames (frame types 1a, 1a plus intramedullary pin [1aIMP], 1b and 2b) was evaluated. The mean time to clinical union was 65 days. All cases treated with 1b, 2b or 1aIMP frames healed. Four of 25 cases treated with 1a frames failed to heal due to premature pin loosening; these failures were in heavier patients than 1a cases which healed (P=0·041). Complications occurred in 40 of 62 cases, and were more common in cases treated with type 2b frames. Pin loosening was the most frequent complication (35 cases) and most commonly involved the most proximal pin (P |
---|---|