Simultaneous EEG-Correlated Ictal fMRI

The ability to continuously acquire simultaneous EEG and fMRI data during seizures presents a formidable challenge both clinically and technically. Published ictal fMRI reports have so far been unable to benefit from simultaneous electrographic recordings and remain largely assumptive. Unique findin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NeuroImage (Orlando, Fla.) Fla.), 2002-05, Vol.16 (1), p.32-40
Hauptverfasser: Salek-Haddadi, Afraim, Merschhemke, Martin, Lemieux, Louis, Fish, David R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The ability to continuously acquire simultaneous EEG and fMRI data during seizures presents a formidable challenge both clinically and technically. Published ictal fMRI reports have so far been unable to benefit from simultaneous electrographic recordings and remain largely assumptive. Unique findings from a Continuous EEG-correlated fMRI experiment are presented in which a focal subclinical seizure was captured in its entirety. For the first time dynamic and biphasic Blood Oxygen Level Dependent (BOLD) signal changes are shown using statistical parametric mapping time-locked to the ictal EEG activity localizing seizure generation and propagation sites, with millimeter resolution, to electroclinically concordant gray matter structures. Though presently of limited clinical applicability, a new avenue is opened for further research.
ISSN:1053-8119
1095-9572
DOI:10.1006/nimg.2002.1073