Biomechanical investigations of different osteosynthesis procedures in the proximal tibia-introduction of a new measuring system

In this article a new measuring system for biomechanical studies of various osteosynthesis procedures on the tibia is described. The paired tibias are osteotomized and embedded in PMMA in accordance with a randomization protocol. Testing is then carried out under nonaxial loading at 350 N, 600 N and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedizinische Technik 2003-11, Vol.48 (11), p.319-324
Hauptverfasser: Mehler, D, Hansen, M, Rommens, P M
Format: Artikel
Sprache:ger
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this article a new measuring system for biomechanical studies of various osteosynthesis procedures on the tibia is described. The paired tibias are osteotomized and embedded in PMMA in accordance with a randomization protocol. Testing is then carried out under nonaxial loading at 350 N, 600 N and 900 N, uniaxial bending applying a force of 12 Nm, and torsion at a force of 5 Nm in a universal pneumatic testing machine. Ultrasonic sensors pick up movement at the fracture gap under external loading. Testing of the measuring setup has been successful, and relevant results were obtained.
ISSN:0013-5585