Medtronic freestyle valves in right ventricular outflow tract reconstruction

Various pulmonary valve substitutes, with their inherent limitations, have been used in children and young adults. We chose the Medtronic Freestyle (Medtronics, Minneapolis, MN) valve because of its excellent hemodynamics, known durability in adults, and design features that allow modifications duri...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2003-12, Vol.76 (6), p.1896-1900
Hauptverfasser: Hartz, Renee S, Deleon, Serafin Y, Lane, Jason, Dorotan, Jamie, Joyce, James, Urbina, Elaine, Ross-Ascuitto, Nancy, Ascuitto, Robert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Various pulmonary valve substitutes, with their inherent limitations, have been used in children and young adults. We chose the Medtronic Freestyle (Medtronics, Minneapolis, MN) valve because of its excellent hemodynamics, known durability in adults, and design features that allow modifications during implantation. Over a 3 1/2 year period the Freestyle valve was implanted in 47 patients age 2 to 58 years (mean 14.2, median 12.0) in the pulmonary position. All patients had pulmonic stenosis and(or) insufficiency from previous operations for tetralogy (27), pulmonary atresia (6), truncus (4), or other diagnosis (10). The indication for surgery was pure pulmonary insufficiency in 11 patients, pulmonic stenosis in 3, and mixed stenosis and insufficiency in 33. Root replacement technique was used with additional enlargement of the pulmonary artery branches in 10 patients. Intraoperatively, one patient sustained a right ventricle tear and one a circumflex coronary artery injury during the dissection. There was one postoperative death. Two patients developed late subvalvular pannus formation, one of whom required reoperation. One patient was found to have an echo gradient of 95 mm Hg due to decreased leaflet motion and underwent cardiac catheterization at which the peak systolic gradient was determined to be 50 mm Hg. He has not required reintervention during his 3 1/2 years of follow-up. The remaining 43 patients have minimal gradients or insufficiency. All surviving patients are in New York Heart Association (NYHA) Class I. The Medtronic Freestyle valve is an attractive alternative for RVOT (right ventricular outflow tract) reconstruction in children. It is readily available, versatile, and has excellent hemodynamic characteristics. Although long term follow-up is not yet available, longevity of this prosthesis, and freedom from complications, will hopefully be superior to valves with stents.
ISSN:0003-4975
1552-6259
DOI:10.1016/S0003-4975(03)01301-8