Closure of an iatrogenic aortocoronary arteriovenous fistula: Transcatheter balloon embolization following failed coil embolization and salvage of coils that migrated into the coronary venous system

We report a 50‐year‐old patient with successful percutaneous closure of a large inadvertent surgical aortocoronary arteriovenous fistula (shunt flow: 1.8 L/min). With initial embolization of multiple coils, no lasting occlusion of the large fistula could be achieved. Above that, two coils migrated i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2002-01, Vol.55 (1), p.109-112
Hauptverfasser: Maier, Lars S., Buchwald, Arnd B., Ehlers, Björn, Rühmkorf, Klaus, Scholz, Karl H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report a 50‐year‐old patient with successful percutaneous closure of a large inadvertent surgical aortocoronary arteriovenous fistula (shunt flow: 1.8 L/min). With initial embolization of multiple coils, no lasting occlusion of the large fistula could be achieved. Above that, two coils migrated into the coronary venous system. Following rescue of the migrated coils through a retrograde coronary sinus approach, the fistula was occluded using a detachable balloon. Follow‐up angiograms confirmed successful closure of the fistula. In contrast to coil embolization, use of a detachable balloon seems to be the appropriate technique for percutaneous closure of such fistulas. Cathet Cardiovasc Intervent 2002;55:109–112. © 2002 Wiley‐Liss, Inc.