A prospective study of a hand-held ultrasound device in abdominal aortic aneurysm evaluation

Effective treatment of abdominal aortic aneurysm (AAA) requires both early detection and timely repair to reduce aneurysm-related mortality. The purpose of this prospective study was to evaluate the utility of a hand-held ultrasonography (US) device in AAA screening in a Veterans Affairs vascular su...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of surgery 2003-11, Vol.186 (5), p.455-459
Hauptverfasser: Lin, Peter H, Bush, Ruth L, McCoy, Sally A, Felkai, Deborah, Pasnelli, Terrance K, Nelson, John C, Watts, Kenneth, Lam, Russell C, Lumsden, Alan B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Effective treatment of abdominal aortic aneurysm (AAA) requires both early detection and timely repair to reduce aneurysm-related mortality. The purpose of this prospective study was to evaluate the utility of a hand-held ultrasonography (US) device in AAA screening in a Veterans Affairs vascular surgical service. During a 16-month period, patients with risk factors for AAA were evaluated in a blinded fashion with a hand-held US device performed by physicians. A conventional abdominal duplex US examination was also performed by a certified vascular ultrasonographer. Results of the hand-held US was compared with the conventional duplex US examination. A total of 104 patients were evaluated (97 men, mean age 67 ± 6.3 years). The mean times for hand-held and conventional duplex US examinations were 5.3 ± 3.2 minutes and 3.1 ± 2.4 minutes (not significant), respectively. Using the conventional duplex US as a reference, the sensitivity and specificity of the hand-held device in detecting a AAA were 93% and 97%, respectively. The positive and negative predictive values of the hand-held device were 89% and 98%, respectively. The likelihood ratios of positive and negative tests of the hand-held US device examination were 82 and 0.14, respectively. The diagnostic accuracy of the hand-held US device as compared with the conventional duplex US was 98%. A hand-held portable US device is effective and accurate in AAA screening with results comparable to the conventional abdominal duplex examination. Moreover, hand-held portable US for AAA screening can be performed expeditiously during physical examination. It should be used as an extension in routine physical examination in vascular patients.
ISSN:0002-9610
1879-1883
DOI:10.1016/j.amjsurg.2003.07.018