Initial energy for elective external cardioversion of persistent atrial fibrillation
We conducted a prospective randomized study to determine the safety and efficacy rate of 3 commonly used energy levels (100, 200, and 360 J) for elective direct-current cardioversion of persistent atrial fibrillation. When compared with 100 and 200 J, the initial success rate with 360 J was signific...
Gespeichert in:
Veröffentlicht in: | The American journal of cardiology 2000-08, Vol.86 (3), p.348-350 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We conducted a prospective randomized study to determine the safety and efficacy rate of 3 commonly used energy levels (100, 200, and 360 J) for elective direct-current cardioversion of persistent atrial fibrillation. When compared with 100 and 200 J, the initial success rate with 360 J was significantly higher (14%, 39%, and 95%, respectively), and patients randomized to 360 J ultimately required less total energy and a lower number of shocks. |
---|---|
ISSN: | 0002-9149 1879-1913 |
DOI: | 10.1016/S0002-9149(00)00932-2 |