Determination of tilmicosin residues in cow and sheep milk by liquid chromatography

This method was developed and validated to detect and quantitate tilmicosin residues in cow milk over a range of 0.010-10 microg/mL, and in sheep milk over a range of 0.025-0.5 microg/mL. The procedure involves extracting the milk sample with acetonitrile and using a C18 cartridge to perform a solid...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of AOAC International 2000-05, Vol.83 (3), p.555-562
Hauptverfasser: STOBBA-WILEY, C. M, READNOUR, R. S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This method was developed and validated to detect and quantitate tilmicosin residues in cow milk over a range of 0.010-10 microg/mL, and in sheep milk over a range of 0.025-0.5 microg/mL. The procedure involves extracting the milk sample with acetonitrile and using a C18 cartridge to perform a solid-phase extraction cleanup of the extract. A reversed-phase gradient liquid chromatography method with detection at 280 nm is used to separate the tilmicosin from matrix components in a 30 min run time. The limit of quantitation of the method is 0.010 microg/mL for cow milk, and 0.025 microg/mL for sheep milk. Average percentage recoveries for milk samples ranged from 82 to 94%. Percentage relative standard deviation values ranged from 3.1 to 17.2%.
ISSN:1060-3271
1944-7922
DOI:10.1093/jaoac/83.3.555