Only carbon dioxide absorbents free of both NaOH and KOH do not generate compound A during in vitro closed-system sevoflurane: Evaluation of five absorbents
Insufficient data exist on the production of compound A during closed-system sevoflurane administration with newer carbon dioxide absorbents. A modified PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow at the top of the bellow approximately/= 160 ml/min...
Gespeichert in:
Veröffentlicht in: | Anesthesiology (Philadelphia) 2001-09, Vol.95 (3), p.750-755 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Insufficient data exist on the production of compound A during closed-system sevoflurane administration with newer carbon dioxide absorbents.
A modified PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow at the top of the bellow approximately/= 160 ml/min CO2; outflow at the Y piece of the lung model approximately/= 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure of approximately 40 mmHg. Various fresh carbon dioxide absorbents were used: Sodasorb (n = 6), Sofnolime (n = 6), and potassium hydroxide (KOH)-free Sodasorb (n = 7), Amsorb (n = 7), and lithium hydroxide (n = 7). After baseline analysis, liquid sevoflurane was injected into the circuit by syringe pump to obtain 2.1% end-tidal concentration for 240 min. At baseline and at regular intervals thereafter, end-tidal carbon dioxide partial pressure, end-tidal sevoflurane concentration, and canister inflow (T degrees(in)) and canister outflow (T degrees(out)) temperatures were measured. To measure compound Ainsp concentration in the inspired gas of the breathing circuit, 2-ml gas samples were taken and analyzed by capillary gas chromatography plus mass spectrometry.
The median (minimum-maximum) highest compound Ainsp concentrations over the entire period were, in decreasing order: 38.3 (28.4-44.2)* (Sofnolime), 30.1 (23.9-43.7) (KOH-free Sodasorb), 23.3 (20.0-29.2) (Sodasorb), 1.6 (1.3-2.1)* (lithium hydroxide), and 1.3 (1.1-1.8)* (Amsorb) parts per million (*P < 0.01 vs. Sodasorb). After reaching their peak concentration, a decrease for Sofnolime, KOH-free Sodasorb, and Sodasorb until 240 min was found. The median (minimum-maximum) highest values for T degrees(out) were 39 (38-40), 40 (39-42), 41 (40-42), 46 (44-48)*, and 39 (38-41) degrees C (*P < 0.01 vs. Sodasorb), respectively.
With KOH-free (but sodium hydroxide [NaOH]-containing) soda limes even higher compound A concentrations are recorded than with standard Sodasorb. Only by eliminating KOH as well as NaOH from the absorbent (Amsorb and lithium hydroxide) is no compound A produced. |
---|---|
ISSN: | 0003-3022 1528-1175 |
DOI: | 10.1097/00000542-200109000-00030 |